Manual Now ENG

Pairing Generator Master





As soon as the GM is connected, the orange led light will start blinking continuously to detect the absent connection with the CU.

Keep the button pressed for 5 seconds, until the orange led light starts blinking less frequently.

To complete the pairing, go to the Control Unit.



On the Home screen, press the bottom right key .



Press the "Installation" button.



Press button 3 "Generator Master".



Press the green button "Pairing".

The icon starts blinking and "’Pairing in progress" appears. Wait until the operation is over (about 20 seconds).

Repeat the operation in case the GM pairing fails and the warning symbol appears.

It may be necessary to reset the Generator Master if the pairing continues to fail: press the button for about 30 seconds, until all 3 LEDs turn on. Repeat the operations from the beginning of the paragraph.



Select the desired button on the Generator Master:

• Heat Generator command (only one device can be set up this way),

• Single Pump command (only a maximum of 8 GM can have this function),

• Heat Generator setpoint command (with double set point HIGH – LOW),



Use the keyboard to confer a name to the GM paired.

Once the operation is over, confirm by clicking on the bottom right key.

To set up the GM working schedule, see paragraph "Settings" » "Managing the GM".