Manual Now ENG

Generator Master Built-in





The Generator Master Built-In is provided with a supplied wall support for the electric charge and a plate for being installed in the electrical junction box.

The device can be configured by the Control Unit to:

- provide the signal for the ignition or shutting down of the heat generator;

- provide the signal to control the setpoint for the heat generator operation (only for requiring boilers);

The details for the connection to the electricity grid are on the leafet.

Generator Master Built-in
Power supply 230V - 50-60Hz
Display Led
Output Relay 5A 250 Vac
Transmission frequency (carrier) 868Mhz < 10mW
Electric protection Class II
Protection degree IP 20
Dimensions: 87x87x52 mm
Operating temperature range 0 °C ÷ +40 °C
Storage temperature range -10 °C ÷ +50 °C
Reference Standards EN 60730-1: 2013, EN 61000-6-1: 2007, EN61000-6-3: 2007, EN 61000-4-2: 2009,
EN300220-1/2, EN 301489-1/3, R&TTE1999/5/EC, LVD 2006/95/EC, RoHS 2011/65/EU


NOTE:

The Generator Master has to be installed at least 500 mm from the Control Unit.
The Generator Master is a on/off relay controlled by the Control Unit, but it does not replace for the remote control panel of the heat generator.
For a correct operation of the heat generator, work strictly from the Instruction Manual.